An error in the built in Shutdown Integrity Test in the RMA 1822A RMS software could lead to a fault in the +27V power relay on the PS 1227 board for transmitter 1, used by the Terminator on the TCA board to remove the voltages to the transmitter, not being detected.
The criticality is removed by using the correct test procedure for the Annual Shutdown Integrity Check. On a long term basis to maintain the flexibility and high integrity of the Normarc 7000B Rev.3 and Rev.4 cabinets a mandatory upgrade of the software on the RMA 1822A boards is required.
In addition to the Customer Information the download includes Upgrade Procedure document - UILS892 , the NMS307 RMS Update Utility and the new software NMS280 vers. 3.3 for the RMA 18222A board.
This is all documents and software needed to carry out the upgrade.
As some of our customers have experienced problems to download the "CI1421 Complete package.zip" file due to that it contains two exe-files, we have now also provided a password protected zip-fil with the name "CI1421 Complete package.rename_to_zip". This might be easier to download, then rename it to "CI1421 Complete package.zip" and then unpack/open it.
The password for this file is: Normarc